If the cFos Charging Manager cannot find the SunSpec registers because the start address for your unit is not 40000, 40001 or 50000, you can specify them in the 'SunSpec Start Register' input field.
If your unit supports multiple SunSpec models, you can skip the first n models by entering n (e.g. 1,2,3,... etc.) in the 'SunSpec Model Index' entry field. This is useful if, for example, the inverter and other meters are housed in one unit.
Under 'SunSpec Model' you can select whether inverters, meters or battery storage units are to be searched for. Some battery storages are shown by the manufacturer under "MPPT Module". If you select this, the model index indicates which MPPT module you want to read out. Note: The DC values of the MPPT modules may be slightly higher than the actual usable AC power, as losses occur during conversion. This can slightly distort the calculation of the solar surplus.
If necessary, add a SunSpec model index:
1 (Standardwert) | M103 Solar inverter |
2 | M203, root meter |
3 | M203, additional solar power |
If you want to use E3/DC Simple Mode instead of SunSpec, you can enter a register number as an additional parameter. If you have installed additional power meters, you can also select these from 0-7. The power meters are freely configurable and differ depending on the system. You must try out which value (grid consumption, PV generation, battery) is recorded by the power meter. The advantage of the power meters is that the cFos Charging Manager receives values from these per phase and not just a single total power value.
40068 | Inverter power |
40070 | Battery power |
40072 | Home power consumption |
40074 | Total power consumption |
40076 | Additional solar power |
40078 | Consumed additional EVSE power |
40105 | Powermeter 0 |
40109 | Powermeter 1 |
40113 | Powermeter 2 |
40117 | Powermeter 3 |
40121 | Powermeter 4 |
40125 | Powermeter 5 |
40129 | Powermeter 6 |
67 | Inverter power / PV production (internal) |
69 | Battery power |
71 | Own power consumption / Home consumption |
73 | Total electricity consumption / Grid power (purchase/feed-in) |
75 | Additional solar power / PV production (external) |
Thanks to Manuel G. for all the help!